Stuck in defrost
If your heat pump won't come out of defrost, the house keeps losing heat and the backup element may end up carrying the load, which costs more to run.
Find a pro near meTell a local repair pro what your heat pump is doing.
You walked outside in January and saw your heat pump blowing what looked like steam, or it just sat there quiet for ten or fifteen minutes doing nothing while the house cooled off. That's defrost mode. Your heat pump moves heat from the outside air into your house even when it's cold out, and in New Mexico's dry winter air, frost can still build up on the outdoor coil overnight or during a cold snap. When it does, the system reverses itself for a few minutes to melt that frost off, then switches back to heating. It's supposed to happen. The problem is when it happens too often, runs too long, or the unit comes out of it and doesn't go back to heating right.
If your heat pump is cycling into defrost every hour instead of every couple hours, or if it's stuck blowing cold air afterward, something's off. It could be a defrost sensor that's failing, a reversing valve that's sticking, or a low refrigerant charge making the coil run colder than it should. None of that is something to guess at over the phone or figure out from a forum post. It takes someone standing at your unit with gauges.
That's where a local contractor comes in, one who works on heat pumps through the winter here and has seen what usually causes a defrost cycle to go wrong in this climate. You get matched with one contractor, not a handful calling and texting you at once. They know gas furnace backup systems are common here too, so they'll check whether your heat pump and any auxiliary heat are working together the way they should, or working against each other.
Tell them what you saw and when you saw it. That's the fastest way to get to what's actually wrong.
You've felt it: the air coming out of the vents turns cool, or the whole system just stops for a while, right when it's cold outside and you need the heat most. It's easy to think something's broken. Most of the time it isn't. New Mexico winter nights can get well below freezing, especially away from the city, and that cold is exactly what triggers this.
Cold, dry New Mexico air still carries enough moisture to frost the outdoor coil when temperatures drop toward freezing. Once that frost builds up, the coil can't pull heat from the air anymore, so the system reverses itself for a few minutes, sends warm refrigerant outside to melt the ice, and runs its outdoor fan backward or not at all. While that's happening, the indoor air can feel cool or stop moving, because the heat is going into melting ice, not into your living room. A backup heat strip or your furnace, if you have gas heat tied into the system, may kick in during this stretch to keep the house from feeling the dip. Once the coil is clear, it switches back to normal heating on its own.




Your request goes to one pro, not a list of companies.
Asking costs nothing, and the choice to hire stays yours.

A sensor on the outdoor coil tracks its temperature, and a second one tracks the outside air. When the coil runs cold enough for frost to form, usually below freezing, the control board starts timing. Most systems check every 30 to 90 minutes. If the coil is still too cold when that timer runs out, the system reverses itself and starts the defrost cycle, whether or not you'd notice frost yourself.

During defrost, the outdoor fan shuts off. Running it would blow cold air across the coil while the system is trying to warm it up, working against the whole point of the cycle. With the fan off and the system running in reverse, the coil heats up fast and sheds the frost in a few minutes. That's also why the unit looks dead from outside even though it's doing exactly what it should.


If your heat pump won't come out of defrost, the house keeps losing heat and the backup element may end up carrying the load, which costs more to run.
If the outdoor coil never defrosts, frost builds up and blocks airflow until the unit can't pull heat from the air, leaving your house cold on a winter night.


At 14.85 cents a kilowatt-hour, every minute your heat pump spends stuck in defrost and leaning on the backup heat strip adds up fast on your bill. A system that defrosts right and gets back to heating keeps that cost where it should be.
EIA-861 2025 statewide residential average
The coil sensor reads a temperature cold enough for frost to form.
The control board reverses the reversing valve to send hot gas outside.
The outdoor fan shuts off so heat stays on the coil.
Indoor air runs cool or stops while backup heat may kick in.
A heat pump that defrosts the way it's supposed to is doing its job, even on the days it looks like it's struggling. Short cycles of steam, a few minutes of cool air, the system back to heating on its own: that's normal, and nothing to call anyone about. What's worth a call is a system stuck in defrost, one that never defrosts at all, or backup heat that's running more than it should on a cold New Mexico night. If that's what you're seeing, you're better served by one contractor who knows heat pumps in this area and sees this exact problem every winter, not a handful of companies competing for the job. They'll know whether it's the sensor, the control board, or the reversing valve before they even get to your house, because they've likely already seen it on someone else's this season. You'll get matched with that one local, licensed contractor, and they'll reach out to you directly.