Normal running sound
A steady hum from the outdoor unit on a cold night is the fan and compressor doing their job. You might hear a brief gurgle or hiss when the defrost cycle kicks in, then the sound settles back to a low, even whoosh.

No phone calls to make
Cold snaps bring a different noise out of a heat pump than it makes the rest of the year, and it's not always clear if that clicking or hissing means trouble or just the defrost cycle doing its job. This page walks through what's normal for a New Mexico winter and what points to a part that needs a look. Skip calling around to find someone who actually works on heat pumps in the cold here. You'll get matched with one licensed local contractor who already knows what tends to go wrong this time of year, instead of explaining the noise over and over to company after company.
Start one formA heat pump works harder on a cold New Mexico night than it does any other time of year, and that's usually what you're hearing. A low hum or whoosh is the outdoor fan and compressor running longer to pull heat out of air that's near or below freezing. A rhythmic clicking at the start or end of a cycle is the reversing valve switching the system into or out of defrost. A hiss right after that switch is hot gas moving through the coil to melt off frost that built up while it ran. These sounds show up more on the coldest nights because the unit is cycling into defrost more often then. What should worry you is a different kind of sound: grinding, screeching, or a clatter that doesn't stop when the cycle changes. That points to a fan motor, a bearing, or a loose part, not the cold doing its normal work.

A steady hum from the outdoor unit on a cold night is the fan and compressor doing their job. You might hear a brief gurgle or hiss when the defrost cycle kicks in, then the sound settles back to a low, even whoosh.

A sharp clank, a loud buzz, or a grinding sound that doesn't go away points to a loose part or a failing motor. If the unit cycles on and off fast, or the noise gets louder over a few days, that's worth having looked at.
That clicking right when the system changes over catches a lot of people off guard, especially late at night when the house is quiet and it's the loudest thing you hear. You want to know if that's just part of how defrost works or a sign the reversing valve is on its way out.
A heat pump heats and cools using the same refrigerant lines, and the reversing valve is what flips the flow between the two. When outdoor temperatures drop toward freezing, the system checks the outdoor coil and switches into defrost to melt off any frost that's built up, then switches back to heating once it's clear. Each time that valve moves, it makes a clunk or click as the internal slide shifts into position. This happens several times during a cold night and is normal. What's not normal is a loud, repeated clanking or a click that's followed by the system blowing cold air and never switching back to heat.




A night or two of clicking and buzzing through defrost cycles during a cold snap isn't something to worry about. The trouble starts when the unit is still running loud after the sun's up, or when the outdoor fan sounds like it's straining against ice it can't shake off. That's extra work the system shouldn't have to do, and it's work you pay for whether or not anything ever breaks. A reversing valve on its way out or a refrigerant charge that's dropped low enough will make the defrost cycle sound rougher and take longer to settle, and the heat pump will lean harder on your gas furnace to keep the house warm in the meantime. You'll notice that in how often the furnace kicks on before you ever see it on a bill. The sound itself is the early warning. A noise that doesn't match what you heard from the same unit last winter, or one that shows up suddenly, is worth having looked at before the next cold night in the teens asks more of it than it can give.



Your request stays with one local pro.
Fill out one short form instead of calling around.
You're not committing to anything by asking.


The whole defrost cycle runs on a loop between a sensor, a valve and the control board, and most of what you hear is one of those three doing its job. On a cold night, frost builds up on the outdoor coil faster than it melts off on its own. A sensor mounted on that coil reads the buildup and reports it to the control board inside the unit. Once it crosses the point the board is set to catch, the reversing valve throws, and that's the thunk you hear under the hum, not a knock or a part coming loose. Throwing the valve sends hot refrigerant backward through the outdoor coil to melt the ice instead of pulling heat from the air. The outdoor fan shuts off for the few minutes this takes, since blowing cold air across the coil right then would fight the melt instead of helping it. That's why the sound drops and changes instead of climbing, even though the compressor is still running the whole time. A heat strip often switches on inside at the same time, so the air coming out of your vents doesn't go cold while the outdoor unit is mid cycle, and that adds a low hum of its own. Once the coil reads clear, the valve throws back, you'll hear the second thunk, and the fan kicks back on. The whole sequence usually runs a few minutes on a cold night and repeats as often as the coil needs it.
A heat pump run harder by cold air pulls more power to do it, and at 14.85 cents a kilowatt-hour that shows up on your bill before you ever hear a strange noise. If a noisy unit is also running longer than it used to, that's the part worth having a tech check.
EIA-861 2025 statewide residential average

This is a heat pump doing normal winter work. The lines run clean to the disconnect box, the pad sits level, and the sound coming off it is just the fan and compressor pulling heat out of cold air. Nothing here needs a second look.

Same setup, same spot by the wall, but something's off. If this unit is grinding, rattling at the disconnect, or running long after sunrise on a cold morning, a New Mexico tech who works on heat pumps all winter can tell you fast whether it's the reversing valve, a loose part, or a motor on its way out.

New Mexico summers don't feel as heavy as the heat alone suggests, because the air stays dry, averaging a dew point of 45°F across June, July and August. That dryness is part of why the same heat pump sounds different once winter cold sets in. Dry outdoor air holds less moisture to begin with, but once temperatures drop toward freezing, whatever moisture is there lands on the outdoor coil as frost rather than staying airborne. That's what sends the system into defrost and brings on the clicks and hisses you don't hear in July. The noise isn't the unit struggling with summer heat catching up with it later. It's a separate job the same equipment does only in cold weather. Source: NOAA climate normals
NASA POWER T2MDEW county cells weighted by homes



A hum that holds steady, a thunk when defrost kicks in, a hiss that settles back down within a few minutes. That's a heat pump working through a cold night, nothing more. Grinding, screeching, or banging that doesn't fit that pattern, or a unit that's still running loud well after sunrise, is the system telling you something is wearing out or coming loose.
If you've gotten this far wondering whether to make a call, you already know which one you heard. Instead of searching through contractors, calling a few, and walking each one through the same story about what the noise sounds like and when it started, you can put that in front of one licensed tech local to New Mexico who hears this exact thing on heat pumps every winter. You explain it once, to someone who already knows what a reversing valve or a failing fan motor sounds like in cold weather, and go from there.